Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI LabVIEW 8.6.1 Win32Eng LV8.6.1 32位英文版下载
http://pcmv.cn/thread-22766-1-1.html?fromuid=9
(出处: 机器视觉论坛)
Click the Update button in the Preview Pane of the LabVIEW MathScript Window to synchronize the value of the variable you select from the Variable List with the same value in any location where the variable appears in MathScript, including outside the LabVIEW MathScript Window. If you change the value of the variable in the Preview Pane, click the Update button to send the new value to any location where the variable appears in MathScript. If you do not change the value of the variable in the Preview Pane, click the Update button to refresh the variable with the latest value from another location in MathScript.
The quad MathScript function is not supported in the LabVIEW Run-Time Engine. You cannot use this function in a stand-alone application or shared library.
If you install LabVIEW 8.6.x or the latest NI Device Drivers media without upgrading to LabVIEW SignalExpress 3.0, some SignalExpress VIs break after code generation. Refer to the National Instruments Web site for more information about repairing code generation and upgrading to SignalExpress 3.0.
The Wait (ms) function behaves differently on Windows and the LabVIEW Real-Time Module. On Windows, the Wait (ms) function waits up to the value specfied in the milliseconds to wait input. On the RT Module, the Wait (ms) function waits at least the value you specify in the milliseconds to wait input. The Wait (ms) function has a margin of error of plus or minus one millisecond.
ID | Legacy ID | Fixed Issue |
44114 | 4GPD8CUD | Using Reinitialize to Default Value on XControl resets data, but not the display of the control. |
57016 | 44DLSS7Q | Major grids disappear on waveform graph |
90672 | 400C2N00 | The server.tcp.acl config token is not copied over during a build application |
100582 | - | NIReport.llb: "report in" and "report out" parameters are not localized in any of the VIs |
106270 | - | Custom probes not cached for any wire type that has an embedded LabVIEW class (cluster, array, refnum) |
109046 | - | Custom probe of any type containing LabVIEW class doesn't show up in Custom Probe menu |
109454 | - | Custom Wire Artwork does not immediately redraw when replacing LabVIEW class |
110820 | - | Right-click copy data in reentrant clones crashes LabVIEW when nested typedefs are involved |
112372 | - | LabVIEW installer "insufficient OS" dialog has a trailing " " |
113638 | - | Connectivity palette is not set to sync to directory, but should |
115082 | - | Application Builder[LV DVD] Product missing in the LV startup dialog box |
115978 | - | Breakpoint Failure |
116663 | - | MathScript in Linux - Pop up plot freezes after saving an eps image. |
116882 | - | Negative constant wired directly to count terminal (N) of For Loop with auto-indexing output tunnels produces "out of memory" error or crash |
117216 | - | Instrument Driver Project Wizard reports empty dependency error in report |
117382 | - | Application builder requests password for dynamic VI |
117659 | - | Control drag copy of multiple controls within a cluster throws internal error |
117709 | - | Unbundling class private data control elements by name follows different rules than regular typedefs |
118210 | - | Language info is not shown at uninstallation dialog |
118665 | - | In-place Variant To/From Element is always broken |
118826 | - | Numeric localization codes do not work |
119144 | - | Wide string caching is very problematic for SCC case sensitivity issues, causes other odd behavior |
119615 | 4EI92JAI | Application created after converting a build script is missing menu bar |
119890 | - | LabVIEW UDP Broadcast on Multiple NICs Does Not Work On Vista |
119916 | - | Perforce Command Line provider slower than Perforce SCM on operations involving large number of files. |
120012 | - | NI_AB_API_SDIST Build.vi displays popup dialogs |
120048 | - | lvanlys.out and lvblas.out have duplicate symbols |
120322 | - | crash after running express save for previous |
120393 | - | The Web server returns a 405 error in response to PUT requests |
120456 | - | Loading a Model in the Sensor Mapping Express VI Crashes LabVIEW |
120749 | - | Can't drag and drop test file items into libraries |
120751 | - | Add UTF preference pages to built-in preferences dialog |
120793 | - | dependencies that don't report callers |
121448 | - | ni::variable::Variable leaks a Variant |
121526 | - | Loading a class when its ancestry is reserved can crash |
121636 | - | LabVIEW hangs on 3D_Graph when running Analyzer test if SCC is enabled. |
121671 | - | Switching to "Files" tab is slow with large project |
121833 | - | Alarm dialog rounds alarm limits to integers when opened - erases previous settings |
121889 | - | Conditionally used variable actually used as variable definition in nested if statement |
121981 | - | MathScript Node breakpoint popup behavior is different when VI is running |
122079 | - | Application Builder build spec ignores remove front panel and block diagram flags at build time for the items listed in the dependencies node of the project tree. |
122604 | - | Possibly Corrupt Type Def Cluster Controls will not print in multiple versions of LabVIEW |
122856 | - | The XControl Facade does not get the Panel Resize event when the XControl is inside a reentrant clone |
122857 | - | Bundle by Name does not work for XControls which contain Cluster Typedefs |
123115 | - | The feedback node terminals can turn black and lose data type when connected to structures |
123312 | - | 100ms delay when sending small packets with Logos XT on VxWorks |
123406 | - | Upgrade llb from 8.5 to 8.6 - llb now crashes whenever you click the broken run arrow |
123618 | - | Incorrect behavior of copy and paste XControl. |
123651 | - | Labview crashes when you change plot names in mixed signal graph |
123716 | - | Unflattening LV object array from xml results in error |
123728 | - | Decimate Array wired to Feedback Node Initializer within Loop Crashes LabVIEW on Second Iteration |
123755 | - | VI conversion fails within a lvlib |
124319 | - | Call to VI server method App.Get VI.CPTM RC is slower in 8.6 |
124463 | - | LabVIEW Hanging on Launch With Expired VI Analyzer License |
124781 | - | Reverting lvlibs in Project Explorer breaks links |
124804 | - | System Exec VI does not work on Russian Windows XP |
124834 | - | Error 1106 using Unflatten from XML on Class with Enum |
125185 | - | FB Typedef Ring Controls show up as #'s when you create a constant |
125408 | - | Attempt to read consolidated type info from future version VI |
125525 | - | Interpolate 2D throws error -20145 whenever non-square array is input into Z terminal. |
125695 | - | Some dialogs don't allow to input eastern characters |
125724 | - | When the Address Book Web Service example is executed after deployed, the internal server error occurred. |
125835 | - | LabVIEW Remote Front Panel 8.6 on Linux Distribution |
125899 | - | Memory Leak when reading from binary file in While Loop |
126200 | - | Call by Reference crashes LV 8.6 when using application refnum |
128091 | - | Typing values in cursor legend of Intensity graph will crash LabVIEW 8.6 |
128115 | - | Incorrect Behavior in case structure execution |
128247 | - | LabVIEW Call Library Node has incorrect "data type" for Waveforms and therefore does not work in 8.6 |
128520 | - | LabVIEW 8.6 Crashes if TDMS Write has Invalid File Reference |
128657 | - | Locked (No Password) VI property does not save in 8.6 |
129245 | - | Revert VI with function blocks not updating project tree |
129282 | - | The LabVIEW 8.6 Standard Run-Time Engine Installer available online updates the USI component |
129876 | - | Desktop Execution Trace Toolkit help server plug-in doesn't return localized target name |
130294 | - | Digital Graph causes LabVIEW to crash when displaying digital signal subsets |
130634 | - | The search results are broken for lverror.chm in Korean and Japanese |
131181 | - | Web Services application builder servers page broken |
131428 | - | I/O control drop-down commands broken |
131714 | - | Access violation in LabVIEW while using digital waveform graph |
Use a standard text editor to open the LabVIEW.ini file located in the LabVIEW directory.
Add massCompAll=True as a new line at the end of the file.
Save and close the LabVIEW.ini file.
Open LabVIEW.
Select Tools»Advanced»Mass Compile to display the Mass Compile dialog box.
Navigate to the desired directory and click the Current Folder button.
Click the Mass Compile button to force recompile all VIs in that directory.
Click the Done button to return to LabVIEW.
Once you finish the force recompile, reopen the LabVIEW.ini file.
Remove massCompAll=True from the file.
Save and close the LabVIEW.ini file.
128115: Incorrect Behavior in case structure execution