Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI LabVIEW 2013SP1 Win32FRE/GER/JPN/KOR 32位LV2013SP1法语/德语/日语/韩语版下载
NI官方下载地址(可能无效或无法下载完成)(EXE版为NI早期压制,ZIP版为NI后期压制,内容一样):
LabVIEW2013 SP1 32位法语版:
请购买附件下载查看
NI LabVIEW 2013SP1 Win32FRE/GER/JPN/KOR 32位LV2013SP1法语/德语/日语/韩语版下载
http://pcmv.cn/thread-21647-1-1.html?fromuid=9
(出处: 机器视觉论坛)
NI LabVIEW 2013SP1 Win32FRE/GER/JPN/KOR 32位LV2013SP1法语/德语/日语/韩语版下载
http://pcmv.cn/thread-21647-1-1.html?fromuid=9
(出处: 机器视觉论坛)
NI LabVIEW 2013SP1 Win32FRE/GER/JPN/KOR 32位LV2013SP1法语/德语/日语/韩语版下载
http://pcmv.cn/thread-21647-1-1.html?fromuid=9
(出处: 机器视觉论坛)
NI LabVIEW 2013SP1 Win32FRE/GER/JPN/KOR 32位LV2013SP1法语/德语/日语/韩语版下载
http://pcmv.cn/thread-21647-1-1.html?fromuid=9
(出处: 机器视觉论坛)
LabVIEW 2013 Service Pack 1自述文件(适用于Windows)(其它语言版使用中文描述)
Windows | 运行引擎 | 开发环境 |
处理器 | Pentium III/Celeron 866 MHz或同等处理器 | Pentium 4M或同等处理器 |
RAM | 256 MB | 1 GB |
屏幕分辨率 | 1024 x 768像素 | 1024 x 768像素 |
操作系统 | Windows 8.1/8/7/Vista(32位和64位) Windows XP SP3(32位) Windows Server 2008 R2(64位) Windows Server 2003 R2(32位) | Windows 8.1/8/7/Vista(32位和64位) Windows XP SP3(32位) Windows Server 2008 R2(64位) Windows Server 2003 R2(32位) |
磁盘空间 | 407 MB | 3.5 GB(包括NI设备驱动程序DVD中的默认驱动程序) |
颜色选板 | N/A | LabVIEW和LabVIEW帮助包含16位彩色图形。LabVIEW至少需要16位彩色配置。 |
临时文件目录 | N/A | LabVIEW使用专用目录存放临时文件。NI建议预留磁盘空间存放临时文件。 |
Adobe Reader | N/A | 如需搜索PDF格式的LabVIEW用户手册,必须安装Adobe Reader。 |
注:在Windows上使用LabVIEW存在下列限制:
|
LabVIEW 安装指南—LabVIEW、模块和工具包、驱动程序,以及硬件的安装方法。
LabVIEW升级说明—在保留原有VI和项目的基础上,安装LabVIEW新版本的方法、升级和兼容性问题,以及LabVIEW 2013和LabVIEW 2013 SP1新增功能的完整列表。
ID | Fixed Issue |
408914 | Using save for previous on a For Loop containing a subdiagram label in LabVIEW 2013 causes the loop N terminal to appear on top of the subdiagram label |
408955 | Crash when deleting a newly created comment with Automatic Tool Selection turned off |
415901 | When repairing LabVIEW 2013, the service locator dependency is uninstalled |
416470 | Using the Get Waveform Attribute in a subVI can cause incorrect data to be returned to the main VI |
420622 | If an HTTP method VI outputs an analog waveform it cannot be locally debugged |
422680 | Deploying a Web service to the Application Web Server gives an error "NI Application Web Server service is still starting" |
423373 | Under certain conditions, a compiler optimization will cause array shift registers to share memory space |
423385 | In LabVIEW 2013, once a Type Definition is made a Strict Type Def, it cannot be made non-strict |
423616 | If a LabVIEW executable containing .NET is included in an installer, it will fail to run when installed |
425800 | Calling Quit LabVIEW VI will not quit LabVIEW if the calling VI also contains an Event structure handling the Application Instance Close Event |
426140 | Building an installer with VIs that contain unsatisfied dependencies within diagram disable structures fails with "Error Generating Preview" |
429282 | In LabVIEW 2013, including VIs from some libraries causes building an installer to fail with error 1 "Error Generating Preview" |
429509 | LabVIEW 64-bit can crash when passing data to a Call Library Function Node that modifies the input data |
429724 | Under certain circumstances, an internal race condition can cause the LabVIEW UI thread to stop updating front panel objects |
429726 | .NET event callbacks to VIs that are already unloaded cause memory access violations |
430748 | Robust fix needed for .NET events calling back to VI that has already been de-registered |
434571 | In LabVIEW 64-bit manipulating arrays with the Array Subset node can cause LabVIEW to crash |
416470—Using the Get Waveform Attribute in a subVI can cause incorrect data to be returned to the main VI
429509—LabVIEW 64-bit can crash when passing data to a Call Library Function Node that modifies the input data
430748—Robust fix needed for .NET events calling back to VI that has already been de-registered
434571—In LabVIEW 64-bit manipulating arrays with the Array Subset node can cause LabVIEW to crash
打开LabVIEW。
选择工具»高级»批量编译可显示批量编译对话框。
浏览至目标路径,单击当前文件夹按钮。
单击批量编译按钮,对目录中的所有VI进行重新编译。
单击完成按钮返回LabVIEW。
关于在无人值守的情况下,单独安装NI产品的更多信息,见知识库文章4CJDP38M,Automating the Installation of a Single Installer。
关于在无人值守的情况下,安装NI Developer Suite之类产品套件的更多信息,见知识库文章4GGGDQH0,Automating the Installation of a Single Installer。
如需确定当前产品NI Installer的版本,见知识库文章4CJDR18M,How Can I Determine the Type and Version of My National Instruments Installer?。
注 Microsoft Windows 8.x系统的桌面上不再包括NI MAX快捷方式。如需启动NI MAX,可打开“应用”视图或“NI启动器”。 |
当前应用程序环境 | 图标位置 | 锁定操作 |
Windows 8.x桌面 | 桌面任务栏 | 右键单击应用程序并选择固定到任务栏 |
Windows 8.x桌面 | 开始屏幕 | 右键单击应用程序并选择固定到开始屏幕 |
Windows 8.x开始屏幕 | 桌面任务栏 | 右键单击应用程序并从屏幕底部的菜单栏选择固定到任务栏 |
产品 | 信息代码 |
NI LabVIEW | lifecycle |
NI LabWindows™/CVI™ | cvi_lifecycle |
NI Measurement Studio | mstudiolifecycle |
NI TestStand | tslcp |
NI DIAdem | ddlcp |
NI SignalExpress | selcp |
NI VeriStand | nivslifecycle |
<National Instruments>目录下有法律声明。
<National Instruments>SharedMDFLegallicense目录下有最终用户许可协议。
如需使NI产品生成的安装程序中包含法律相关信息,请参考<National Instruments>_Legal Information.txt。