Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI LabVIEW 2012SP1 Win32GER 32位LV2012SP1德语版下载
NI LabVIEW 2012SP1 Win32GER 32位LV2012SP1德语版下载
http://pcmv.cn/thread-502-1-1.html?fromuid=9
(出处: 机器视觉论坛)
LabVIEW 2012 Service Pack 1: Readme zur Windows-Version
Systemvoraussetzungen
Windows | Runtime-Engine | Entwicklungsumgebung |
Prozessor | Pentium III/Celeron 866 MHz (oder gleichwertig) | Pentium 4M (oder gleichwertig) |
RAM | 256 MB | 1 GB |
Bildschirmauflösung | 1024 x 768 Pixel | 1024 x 768 Pixel |
Betriebssystem | Windows 8/7/Vista (32 und 64 Bit) Windows XP SP3 (32 Bit) Windows Server 2003 R2 (32 Bit) Windows Server 2008 R2 (64 Bit) | Windows 8/7/Vista (32 und 64 Bit) Windows XP SP3 (32 Bit) Windows Server 2003 R2 (32 Bit) Windows Server 2008 R2 (64 Bit) |
Speicherplatz | 353 MB | 3,67 GB (einschließlich der Standardtreiber von der NI-Gerätetreiber-DVD) |
Farbpalette | k. A. | LabVIEW und die LabVIEW-Hilfe enthalten 16-Bit-Grafiken. Für LabVIEW ist mindestens eine 16-Bit-Farbtiefe erforderlich. |
Temporäres Verzeichnis | k. A. | LabVIEW benötigt ein Verzeichnis zum Speichern temporärer Dateien. Das Verzeichnis sollte nach Möglichkeit mehrere Megabyte groß sein. |
Adobe Reader | k. A. | Für PDF-Versionen der LabVIEW-Handbücher benötigen Sie den Acrobat Reader. |
Hinweis Nachfolgend werden die Einschränkungen bei der Nutzung von LabVIEW unter Windows beschrieben:
|
Installationshinweise
Installationshinweise zu LabVIEW—Enthält Informationen zur Installation von LabVIEW, Modulen, Toolkits und Treibern sowie zum Anschluss von Hardware.
Hinweise zum Upgrade von LabVIEW—Enthält Informationen darüber, wie Sie vorhandene VIs und Projekte vor Beschädigungen durch das Update schützen können. Des Weiteren beschreibt das Dokument bekannte Probleme bei der Aktualisierung von LabVIEW und alle Neuerungen in LabVIEW 2012 und LabVIEW 2012 SP1.
Nutzung von NI-Software auf Windows 8
Verwenden des NI-Startmenüs
Hinweis Im Gegensatz zu bisherigen Windows-Versionen wird unter Windows 8 keine Desktop-Verknüpfung für MAX mehr angezeigt. Sie können MAX über den Startbildschirm oder im NI-Startmenü starten. |
Anheften häufig genutzter Programme
Aktuelles Programm | Standort des Symbols | Anheftvorgang |
Desktop von Windows 8 | Taskleiste des Desktops | Rechtsklick auf das Programm und Auswahl von "An Taskleiste anheften" |
Desktop von Windows 8 | Startseite | Rechtsklick auf das Programm und Auswahl von "An 'Start' anheften" |
Startseite von Windows 8 | Taskleiste des Desktops | Rechtsklick auf das Programm und Auswahl von "An Taskleiste anheften" in der unteren Menüleiste |
Anzeigen aller Programme
Bekannte Probleme
LabVIEW 2012 SP1 (64 Bit)
Unterstützte Hardware
Unterstützte Module
Zusätze zur LabVIEW-Hilfe
LabVIEW 2012 SP1 wendet ggf. die Compiler-Optimierung auf verschiedenen Computern unterschiedlich an. Daher sind eventuell zusätzliche Schritte erforderlich, um sicherzustellen, dass der binäre Inhalt einer erstellten Applikation auf verschiedenen Computern identisch ist. Informationen zum Reproduzieren von Builds in LabVIEW 2012 SP1 finden Sie auf der Website von National Instruments.
Behobene Fehler
ID | Fixed Issue |
375494 | Improved update rate of front panel control value references |
373305 | Property: Mouse for 2D Picture controls returns incorrect values after using Invoke Method: Reinitialize to Default on the 2D Picture control |
373150 | Error code 3 when running LabVIEW 64-bit applications using NI_AALBase.lvlib, that were installed with installers built in 64-bit LabVIEW Application Builder |
371714 | Slow load time when adding a VI to the Exported VIs List for a DLL |
371651 | LabVIEW Source Control prompts to add vi.lib or instr.lib to source control even if they are to be excluded |
370957 | Specific type of cluster sent over the network may produce incorrect results |
370578 | LabVIEW User Interface responsiveness decreases on Mac OS when many VIs are loaded into memory |
370259 | Custom Waveform Graphs display NaN values incorrectly |
368875 | Slow load and close time for large Application Build specifications |
368466 | Plot visibility check box cannot be toggled for plot 0 on an XY Graph |
368396 | Certain applications built with Application Builder fail to launch |
368000 | Using Property: Owner to get an owning cluster's reference on the cluster's sub-controls returns incorrect value if the sub-control reference came from Property: Controls[] of the owning cluster |
367463 | References returned by Property: Controls[] of a pane containing type definitions are incorrect |
367428 | Private inlined VIs in a library cannot be built into packed project libraries |
366331 | Dynamic event registration of an array of controls fails with Error 1 |
365679 | LabVIEW 3D Picture control does not work with certain AMD video card drivers |
364799 | Selecting the Configure Web Application Server button immediately after preference page load results in 404 error |
364462 | Crash when changing value of typedef constant |
363945 | LabVIEW crashes if changing properties for multiple selected nodes by right-clicking the label |
362925 | Crash when dragging instance of Polymorphic VI from dialog to block diagram |
362576 | Invoke Method: Add File crashes LabVIEW if Path parameter contains too many characters |
362366 | Packed Project Library deployment fails on Real-Time targets |
362018 | Crash when loading some VIs, saved in a previous version of LabVIEW, into LabVIEW 2012 |
361857 | Certain network configurations cause slow loading of NationalInstruments.LabVIEW120.dll |
361839 | Boolean constant & string constants grow to length of label when cluster is type defined |
361666 | Tools»Actor Framework Message Maker... is missing in Linux |
357092 | Cannot use right-click shortcut menu to create items for the reference out terminal of Property Node (XML) or Invoke Node (XML) |
323332 | Control reference returned from CtlRef of an Event Structure is incorrect for Type Definitions |
312538 | Link between .NET Constructor Node and Assembly is sometimes lost even when .NET Assembly exists |
237213 | Event registration refnum of typedef does not update when typedef updates |
212136 | "The VI is not executable. The full development version of LabVIEW is required to fix the errors" dialog on a built app |
184689 | LabVIEW UI is less responsive when displaying NaN values on 3D Surface Graph |
Neukompilieren von VIs zum Beheben von Fehlern
366331—Dynamic event registration of an array of controls fails with Error 1 (Dynamische Ereignisregistrierung eines Arrays schlägt fehl - Fehlercode 1)
Öffnen Sie LabVIEW.
Wählen Sie Werkzeuge»Fortgeschritten»Massenkompilierung, um zum Dialogfeld Massenkompilierung zu gelangen.
Suchen Sie das gewünschte Verzeichnis auf und klicken Sie auf die Schaltfläche Verzeichnis wählen.
Klicken Sie auf die Schaltfläche Massenkompilierung, um alle VIs im Verzeichnis mit Updates neu zu kompilieren.
Klicken Sie auf Fertig, um zu LabVIEW zurückzukehren.
Automatische Installation von NI-Produkten
Die automatische Installation einzelner NI-Produkte wird in der KB 4CJDP38M, Automating the Installation of a Single Installer, beschrieben.
Die automatische Installation von NI-Produkten innerhalb einer Suite wird in der KB 4CJDP38M, Automating the Installation of a Single Installer, beschrieben.
Die Version des NI-Installers, auf dem das Installationsprogramm Ihres Produkts aufbaut, ist in der KB 4CJDR18M, How Can I Determine the Type and Version of My National Instruments Installer?, beschrieben.
Wichtige Informationen
Rechtshinweise: <National Instruments>_Legal Information und <National Instruments>.
EULAs: <National Instruments>SharedMDFLegallicense
Informationen zum Hinzufügen von Rechtshinweisen zu Installationsprogrammen, die mithilfe von NI-Produkten erzeugt werden: <National Instruments>_Legal Information.txt