Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI LabVIEW 2011SP1 MAC OS X32Eng LV2011SP1苹果系统评估版
NI LabVIEW 2011SP1 MAC OS X32Eng LV2011SP1苹果系统评估版
http://pcmv.cn/thread-22789-1-1.html?fromuid=9
(出处: 机器视觉论坛)
LabVIEW 2011 Service Pack 1 Readme for Mac OS X
In previous versions of LabVIEW, the NewRange event data field for the Scale Range Change event ignores custom offset and multiplier values you set for a graph or chart. In LabVIEW 2011, the NewRange event data field factors in custom offset and multiplier values in the results it returns. In previous versions of LabVIEW, if you use code to work around this issue, you need to update the code in LabVIEW 2011.
ID | Fixed Issue |
202432 | Throw the error with detailed message for the ReserveEPDS function in generated .NET assembly |
241971 | GenLeaInstruction, mapping null reg, EventData copy err=1 errors when debugging an .exe |
288455 | Shared variable not updated when changing representation |
300856 | Unable to use certain smart probes when debugging LabVIEW-built DLLs |
304328 | Typecasting an empty I/O constant to a numeric array crashes LabVIEW |
304531 | Red dot not working correctly for variants |
305157 | LabVIEW crashes when unflattening an empty string to a specific cluster |
305220 | Solve Linear Equations.vi can return incorrect values on Real-Time |
306797 | Cannot create indicator/control/constant for refnum data types from XML property and invoke nodes |
307318 | Crash when merging a change to a class control/indicator |
307687 | Error 1012 merging VIs from command line |
308464 | LabVIEW cannot build some large applications because it fills the image table |
308503 | Marking VIs as NOT source only will crash LabVIEW unless panels/diagrams are force loaded first |
309233 | LabVIEW 2011 crashes when doing a cut and paste of a system checkbox |
309834 | Access violation (0xC0000005) at EIP=0x00764624 |
310077 | Variable browse dialog doesn't show any deployed IOVs |
310513 | LabVIEW can crash when aborting a VI using Asynchronous Call by Reference |
310850 | Internal error (OxA824222F) on user cancel of VI load |
311279 | Deploying a web service will fail |
311460 | Silver XY Graph - palette buttons are wrong color when toggled |
312257 | Executable build fails and locks the LabVIEW User Interface after finishing |
312332 | Charts history changed memory usage between LabVIEW 2010 and LabVIEW 2011 |
313231 | LabVIEW Application Builder cannot deploy Mean.vi when setting passwords to the Analysis library |
314062 | Silver listbox control does not gray disabled item |
315103 | Execution-time crash with Scan Value.vi |
315365 | Enum/Ring control in Silver palette results in Generic Error on save |
315378 | Project loads significantly slow if .lvlps file is present after a build |
315726 | "Prompt for a comment on save VI" during builds |
315878 | Internal error (0xF50EFD7B) |
316379 | Assembly load error 1589 when using '#' in the assembly path |
316408 | LabVIEW 2011 crashes after running and closing a VI that uses packed library |
316606 | Strict typedefs containing a Named IO reference refuse to allow their label to be written via scripting. |
316641 | LabVIEW 2011 does not limit internal warning prints (to the log file) |
316909 | Custom license agreements are not displayed on LabVIEW-built installers |
318426 | Callers of items in packed library that are in subitems don't get their links updated properly. |
320393 | Owner references for controls within a typedef cluster do not match cluster reference |
322188 | VI Revision History "prompt for comment when a VI is closed" doesn't save comment |
316408—LabVIEW 2011 crashes after running and closing a VI that uses packed library
Open LabVIEW.
Select Tools»Advanced»Mass Compile to display the Mass Compile dialog box.
Navigate to the desired directory and click the Current Folder button.
Click the Mass Compile button to force a recompile of all VIs in that directory.
Click the Done button to return to LabVIEW.