Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI Vision Development Module 2013 Win32/64Eng 视觉开发模块VDM2013 适用LabVIEW2013
百度云盘下载:
链接: 请注册视觉论坛会员登陆后购买附件下载查看
提取码: 请购买附件下载查看
NI官方下载地址(可能无效或无法下载完成):
请购买附件下载查看
下载器:
请购买附件下载查看
NI Vision Development Module 2013 Win32/64Eng 视觉开发模块VDM2013 适用LabVIEW2013
http://pcmv.cn/thread-1058-1-1.html?fromuid=9
(出处: 机器视觉论坛)
NI Vision Development Module 2013 Readme
General Information
New Features
Support for LabVIEW 2013 (32- and 64-bit)
Traditional Mean Shift and Shape Adapted Mean Shift algorithms for tracking objects across a sequence of images
New Grayscale Value and Gradient Pyramid pattern matching algorithms. These algorithms enable matching on low-contrast images, robust rotated ROI support, and learning smaller templates.
Improvements to OCR: support for reading multiple lines of text, small rotations of text with the region of interest, more robust segmentation, local threshold, color threshold, and space identification
Support for Japanese and Simplified Chinese for text overlays on Real-Time targets
New examples for LabVIEW 2011, 2012, and 2013
Support for the NI cRIO-9068, NI myRIO-1900, and NI myRIO-1950
Object Tracking step for tracking objects across a sequence of images using Traditional Mean Shift and Shape Adapted Mean Shift algorithms
New Grayscale Value and Gradient Pyramid pattern matching algorithms in the Pattern Matching step. These algorithms enable matching on low-contrast images, robust rotated ROI support, and learning smaller templates.
Improvements to OCR: support for reading multiple lines of text, small rotations of text with the region of interest, more robust segmentation, local threshold, color threshold, and space identification
The Windows Start menu shortcut for NI Vision Assistant is now Start»All Programs»National Instruments»Vision»Vision Assistant
Updates and Improvements
ID | Fixed Issue |
381752 | AVI: Quality is not implemented for the FFmpeg (Vision built-in) codecs. |
404868 | Cannot select Create Control from Vision property nodes. |
412022 | IMAQ Set Calibration Axis Info - Point does not set the axis properly when selected X-axis pixel is at an angle of 90 or -90 degree. |
381293 | No prompt provided to extend Vision products evaluation periods. |
401407 | Vision: error 0xC0000005 when using IMAQ Load Image Dialog VI. |
401363 | Reading AVI frames takes longer and longer when trying to access frames that are further away in the file. |
411876 | In some cases, the Calibration Training Interface does not properly set the calibration axis, resulting in converted pixel to real-world returning wrong coordinates. |
391306 | IMAQ Find Circles VI will cause LabVIEW to crash if too many circles are present. |
386275 | AVI Open/Close has a memory leak on Pharlap. |
386892 | Vision .NET policy redirects not installed for VDM 2011 SP1, 2012, 2012 SP1. |
366342 | IMAQ Count Objects 2 does not work properly as a reentrant VI. |
407934 | IMAQ Overlay Text does not use the User-Specified font on Windows. |
407378 | IMAQ Overlay Text does not support multibyte characters with user-specified font on Windows. |
411378 | The Calibration Training Interface Calibration Axis Angle does not set properly when the user chooses to specify angles in the vicinity of 90 or -90 degrees. |
412895 | NI Template Editor does not error when trying to open an invalid template. |
332875 | Vision Development Module license cannot be activated from the evaluation dialog when launching LabVIEW. |
System Requirements
Minimum | Recommended | |
Processor | 233 MHz Pentium or equivalent | Pentium 4/M or equivalent |
Memory | 256 MB RAM | 512 MB RAM |
Display | 1,024 × 768 resolution video adapter with a 16-bit display | 1,024 × 768 resolution video adapter with a 24- or 32-bit display |
Free Hard Disk Space | 1.4 GB | |
Operating System | Windows 8/Windows 7/Vista/XP (32-bit)/Server 2008 R2/Server 2003 R2 (32-bit) | |
Browser | Microsoft Internet Explorer 6.0 or later |
Remote Target Support
Installation InstructionsInstalling from the LabVIEW Platform DVDs
Installing from the NI Vision Development Module Installation Media
Log on as an administrator or as a user with administrator privileges.
Insert the NI Vision Development Module installation media.
If you do not have autorun enabled, double-click SideCrash1.avi and <CVI>inNIVision.lfp, where <CVI>SamplesVision.
NI Vision for .NET Documentation
NI Measurement Studio Help—Contains reference information about NI Vision for .NET objects. Describes how to create machine vision and image processing applications in Visual Basic .NET and C# using the NI Vision Development Module. You can launch the NI Measurement Studio Help in the following ways:
Trademarks
Patents
From the Windows Start menu, select Start»All Programs»National Instruments»<Measurement Studio>»Measurement Studio Documentation, where <Vision>ExamplesdotNET, where <National Instruments>_Legal Information and <National Instruments>SharedMDFLegallicense directory.
Review <font face="" "="" style="margin: 0px; padding: 0px; overflow-wrap: break-word;"><National Instruments>_Legal Information.txt for information on including legal information in installers built with NI products.