Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI-FGEN 2.8.1 Driver Win32/64 Eng/Jpn NI-FGEN波形发生器仪器驱动程序2.8.1
NI-FGEN
NI-FGEN为使用NI波形发生器产品的客户提供支持。
NI-FGEN是一款NI仪器驱动程序,可实现复杂测量解决方案所需的频率扫描和跳频、波形链接和循环以及频移键控(FSK)调制。 NI-FGEN驱动程序可兼容可互换虚拟仪器(IVI),它具有一系列操作和属性,可以执行波形或信号发生器的功能,并提供交互式软件前面板和示例。
Win32/64Eng/Jpn
2.8.1
文件大小: 1756548497 字节 (1.64 GB)
修改日期: 2011-09-20 05:03
MD5: 5c404c5b189c44d090251d112eaa137a(官方正确)
SHA1: b12e7983e95c625e1d4350a17bf63792b333acef
SHA256: 5d30952145796cbc5dd43b941809b4fa80815a35e24116be1b88e5046d5f1b40
CRC32: e7c32320
百度网盘与NI官方下载地址:
NI-FGEN 2.8.1 Driver Win32/64 Eng/Jpn NI-FGEN波形发生器仪器驱动程序2.8.1
http://pcmv.cn/thread-26317-1-1.html?fromuid=9
(出处: 视觉论坛VISIONBBS|视觉之家VISIONHOME)
NI-FGEN Instrument Driver Readme
New Features
Supported Hardware
System Requirements
Installed File Names and Locations
Documentation
The FGEN Soft Front Panel
Uninstalling/Modifying NI-FGEN
Upgrading Firmware
Known Issues
Bug Fixes
API Changes by Release
Notice Regarding Microsoft Silverlight Installation and Redistribution
New Features
Support for LabVIEW 2011 (32-bit) and LabVIEW 2011 (64-bit).
Support removed for LabVIEW 8.5.1.
Support for peer-to-peer streaming with the NI PXIe-5450 (module revision C only) and NI PXIe-5451.
New firmware for the NI PXIe-5450 and NI PXIe-5451. This firmware upgrade is required for all NI PXIe-5450 and NI PXIe-5451 devices. Refer to Upgrading Firmware for more information about this new firmware.
Support to reset writeable attributes to driver default values. In C, call the niFgen_ResetAttribute function. In LabVIEW, right-click the niFgen Property Node, and select Change To»Default Value.
Support for stream n script instruction.
Support for LabVIEW 2010 (32-bit) and LabVIEW 2010 (64-bit).
Fixed an issue in which a custom installer built on a 32-bit OS using LabVIEW, LabWindows™/CVI™, or NI TestStand does not deploy NI-FGEN or its dependent user applications on a 64-bit OS (ID 228650).
Support removed for LabVIEW 8.2.1.
Fixed a fatal issue when upgrading NI-FGEN 2.7 when using Windows 7 (64-bit) and Windows Server 2008 R2.
Support for the NI PXIe-5451 400 MS/s, 16-bit dual-channel arbitrary waveform generator with onboard signal processing (OSP).
Support for LabVIEW 2009 (64-bit).
Support for 64-bit user mode.
Support for new NI PXIe-5442 and NI PXIe-5450 module revisions.
Support for Standard Function output mode on the NI PXIe-5450 module revision C.
New firmware for the NI PXIe-5442 and NI PXIe-5450. Refer to Upgrading Firmware for more information about this new firmware.
Support for wait with marker and break script instructions.
New VIs, properties, functions, and attributes.
Support for LabVIEW 2009 (32-bit).
Support removed for LabVIEW 7.1.1.
Japanese localization for driver, LabVIEW application programming interface (API), and documentation.
New firmware for the NI PXIe-5450 and NI PXIe-5442. Refer to Upgrading Firmware for more information about this new firmware.
Toggle markers are supported on the NI PXIe-5450.
Reorganized LabVIEW property node and CVI attribute tree.
Support for the NI PXIe-5450 dual-channel I/Q generator with OSP.
Improved scaled write (DBL) performance.
New VIs, properties, functions, and attributes.
Supported Hardware
Hardware Product | Supported Under Windows 7 | Supported Under Windows Vista | Supported Under Windows XP |
NI PXI/PCI-5401 Function Generator | X | X | √ |
NI PXI/PCI-5402 Function Generator | √ | √ | √ |
NI PXI-5404 Frequency Generator | √1 | √1 | √ |
NI PXI/PCI-5406 Function Generator | √ | √ | √ |
NI PXI/PCI-5411 Arbitrary Waveform Generator | X | X | √ |
NI PXI/PCI-5412 Arbitrary Waveform Generator | √ | √ | √ |
NI PXI/PCI-5421 Arbitrary Waveform Generator | √ | √ | √ |
NI PXI-5422 Arbitrary Waveform Generator | √ | √ | √ |
NI PXI/PCI-5431 Video Signal Generator | X | X | √ |
NI PXI-5441 Arbitrary Waveform Generator with Onboard Signal Processing | √ | √ | √ |
NI PXIe–5442 Arbitrary Waveform Generator with Onboard Signal Processing | √ | √ | √ |
NI PXIe–5450 Dual-Channel I/Q Generator with Onboard Signal Processing | √ | √ | √ |
NI PXIe–5451 Dual-Channel Arbitrary Waveform Generator with Onboard Signal Processing | √ | √ | √ |
1 Windows 7/Vista support for the NI 5404 does not include support for external calibration. Perform external calibration for the NI 5404 on Windows XP operating systems. |
MXI type | Supported Under Windows 7 | Supported Under Windows Vista | Supported Under Windows XP |
MXI-3 | X | X | √ |
MXI-4 | √ | √ | √ |
MXI-Express | √ | √ | √ |
System RequirementsSupported Operating Systems
Windows 7 (32-bit and 64-bit)
Windows Vista (32-bit and 64-bit)
Windows XP Service Pack 2 (32-bit)
Windows Server 2003 R2 (32-bit)
Windows Server 2008 R2 (64-bit)
Supported Real-Time Operating Environments
LabVIEW Real-Time Module
LabWindows/CVI Real-Time Module
Minimum System Requirements
Processor—Pentium III/Celeron 600 MHz or equivalent
RAM—
Windows 7/Vista: 512 MB
Windows XP: 128 MB
Microsoft Internet Explorer 5.5 or later
A screen resolution of 800 x 600 with 256 colors
Windows 7/Vista/XP, with all available critical updates and service packs
Recommended System
Processor—Pentium 4 or equivalent
RAM—
Windows 7/Vista: 1 GB
Windows XP: 256 MB
A screen resolution of 1024 x 768
Windows 7/Vista/XP, with all available critical updates and service packs
Application Development Software
NI LabVIEW 8.6.1, 2009 SP1 (32-bit), 2009 SP1 (64-bit), 2010 SP1 (32-bit), 2010 SP1 (64-bit), 2011 (32-bit), or 2011 (64-bit)
NI LabVIEW Real-Time Module 8.6.1, 2009 SP1, 2010 SP1, 2011 (no support for NI PXI/PCI-5401/5411/5431 devices)
LabWindows/CVI 8.5.1 or later
LabWindows/CVI Real-Time Module 9.0 or later (no support for NI PXI/PCI-5401/5411/5431 devices)
Note: If you are running your application on an RT target, at least 128 MB of memory is required.
Measurement Studio 6.0 or later
Microsoft Visual C++ (MSVC) 6.0 or later
Microsoft Visual Basic 6.0
Installed File Names and Locations
<NIDocDir> is an alias for the following National Instruments file folder location:
Windows 7/Vista: UsersPublicDocumentsNational Instruments
Windows XP: Documents and SettingsAll UsersShared DocumentsNational Instruments
<IVIROOTDIR32> is an alias for the following National Instruments file folder location:
Windows 7/Vista/XP 32-bit: Program FilesIVI
Windows 7/Vista 64-bit: Program Files (x86)IVI
Windows 7/Vista/XP 32-bit: Program FilesIVI FoundationIVI
Windows 7/Vista 64-bit: Program Files (x86)IVI FoundationIVI
NOTES: | $(IVIROOTDIR32) is configured as an environment variable on the target system. |
If you upgraded an installation of IVI, your files may be in the following location: |
<IVIROOTDIR64> is an alias for the following National Instruments file folder location:
Windows 7/Vista 64-bit: Program FilesIVI FoundationIVI
NOTE: | $(IVIROOTDIR64) is configured as an environment variable on the target system. |
File Locations
Item | Installed Location on Windows 7/Vista/XP |
NI-FGEN | <IVIROOTDIR32>Drivers iFgen |
NI-FGEN Function Panel | <IVIROOTDIR32>Drivers iFgen ifgen.fp |
NI-FGEN Examples | <NIDocDir>NI-FGENExamples |
NI-FGEN Header files | <IVIROOTDIR32>Include |
NI-FGEN Import Library files | <IVIROOTDIR32>Lib |
NI-FGEN DLL | <IVIROOTDIR32>Bin |
Additional File Locations for Windows 7/Vista 64-bit
Item | Installed Location on Windows 7/Vista 64-bit |
NI-FGEN Function Panel | <IVIROOTDIR64>Drivers iFgen ifgen.fp |
NI-FGEN Header files | <IVIROOTDIR64>Include |
NI-FGEN Import Library files (64-bit) | <IVIROOTDIR64>Lib_x64 |
NI-FGEN DLL (64-bit) | <IVIROOTDIR64>Bin |
Documentation
NI Signal Generators Getting Started Guide
NI Signal Generators Help
Specifications
Calibration Procedures
The FGEN Soft Front Panel (SFP)
Uninstalling/Modifying NI-FGEN
Launch the Control Panel by selecting Start»Control Panel.
Double-click Add/Remove Programs.
Select National Instruments Software.
Click Change/Remove.
Select NI-FGEN 2.8.1 from the dialog box that appears.
Click Remove to uninstall the product; click Modify to change the components that are installed.
Launch the Control Panel by selecting Start»Control Panel.
Double-click Programs and Features.
Select National Instruments Software.
Click the Uninstall/Change button.
Select NI-FGEN 2.8.1 from the dialog box that appears.
Click Remove to uninstall the product; click Modify to change the components that are installed.
NI Hierarchical Waveform Storage 1.4.9
NI IVI Compliance Package 4.4
NI Measurement & Automation Explorer 5.0
Traditional NI-DAQ 7.4.4 (Windows XP only)
NI-DAQmx 9.1.7
NI-VISA 5.0
NI Spy 2.7.2
NI-P2P 1.1.2
Caution Several of the software packages listed above are shared with other NI software packages. If you attempt to remove a piece of software that something else is dependent on, a message launches to warn you about the software dependencies. You can choose to either uninstall all of the software or to leave the shared software installed. If you choose to uninstall the shared software, some of your other NI software may no longer function correctly. |
Upgrading Firmware
Known Issues
LabVIEW FPGA 2010 corrupts error reporting for NI-FGEN, and you may receive the following error message: Error information resources required by the driver could not be found on your system. Reinstall the driver, or contact National Instruments Technical support. Visit ni.com/kb and search for 5C1CGPJD for more information about how to correct error reporting behavior.
Using dynamic FPGA interfaces (also known as dynamic mode) in the LabVIEW FPGA Module is not supported when using peer-to-peer streaming. Dynamic mode is enabled by default in the LabVIEW FPGA Module 2010, so to disable Dynamic mode, complete the following steps:
Place the Open FPGA VI Reference function on the LabVIEW block diagram.
Right-click the function and select Configure Open FPGA VI Reference.
Remove the checkmark from the Dynamic mode listbox.
When you run setup.exe to install the software from the CD, you are prompted to choose whether you want to always trust software from National Instruments. If you do not select this option, your installation may be interrupted by one or more Microsoft Windows security dialog boxes. However, if you run the installer in silent mode from the command line, you do not receive this prompt, and the installer automatically installs NI's Software Publisher Certificate to the your Windows Trusted Publisher Store. If you do not want to make this change to your Windows Trusted Publisher Store, do not choose this installation method.
Windows 7/Vista does not support Traditional DAQ (Legacy) devices. Traditional DAQ devices include the NI PXI/PCI-5401, NI PXI/PCI-5411, and NI PXI/PCI-5431. Simulating these devices is also not supported on Windows 7/Vista, using either the NI-FGEN or the FGEN Soft Front Panel. Simulating a device that is not supported on your operating system results in indeterminate behavior.
If you click a topic link in the NI-FGEN C Function Reference section of the NI Signal Generators Help, you cannot use the Back button in the HTML Help window toolbar to return to the original topic.
Installing NI-FGEN on a system with NI-DAQmx 7.0 or 7.1, NI-FGEN may return an error about NI-FGEN devices unable to start. To work around this issue, install NI-FGEN, reboot, and then repair NI-FGEN using the Microsoft Windows Control Panel.
Bug Fixes
Bug ID | Fixed Issue |
241656 | Fixed firmware to synchronize power supplies for improved phase noise performance. |
199899 | Fixed an issue in which calling calibration utility functions in a normal NI-FGEN session affected output by disabling self-calibration constants. |
182502 | Fixed an issue in which running test panels for the NI PXIe-5450 and NI PXIe-5451 using the LabVIEW Real-Time Module did not write waveform data. This issue caused the output signal to be random. |
183093 | Fixed an issue in which waking from sleep mode could crash the operating system in some configurations, especially if the video, network, or other drivers were out of date. |
187791 | An issue was fixed in which LabVIEW 2009 (64-bit) could crash if you created more than one session using the same resource name. You must install LabVIEW 2009 SP1 (64-bit) for this bug fix. |
Bug ID | Fixed Issue |
228650 | Fixed an issue in which a custom installer built on a 32-bit OS using LabVIEW, LabWindows/CVI, or NI TestStand does not deploy NI-FGEN or its dependent user applications on a 64-bit OS. |
Bug ID | Fixed Issue |
229602 | Fixed an issue with clock configuration that can cause memory corruption or blue screen with certain NI PXIe-5450 devices. |
212209 | Fixed an incorrect calibration DAC setting that could cause self-calibration to fail on the NI PXIe-5451. |
Bug ID | Fixed Issue |
209051 | Fixed an issue in which the installer did not stop service nidevldu before upgrading binaries. |
Bug ID | Fixed Issue |
179935 | Fixed a streaming issue on the NI PXIe-5442/5450. Streaming with certain combinations of chassis and controllers caused the device to return an invalid thermal error and detach itself from the system. You must upgrade your firmware for this solution. |
157714 | Fixed a memory leak that occurred when a session was opened and closed dynamically using VI server on LabVIEW Real-Time targets. |
118345 | Toggle markers are now allowed below 200 MS/s sample rates on the NI PXIe-5450. |
39796 | An error is now returned when PXI_STAR is used as a trigger source for the NI PXIe-5442. This configuration is not supported. |
118500 | The NI PXIe-5450 now supports the Oscillator Phase DAC property and NIFGEN_ATTR_OSCILLATOR_PHASE_DAC_VALUE attribute for external Sample clocks. |
Bug ID | Fixed Issue |
119090 | Fixed an issue that prevented using all device memory for a single-channel generation on channel 1. |
120854 | Fixed a memory leak that occurred when writing less than 128 samples at a time. |
118735 | Fixed an issue that caused the NI 5450 and NI 5442 to skip samples when responding to a Script trigger. |
120220 | Fixed a 16-sample data corruption issue that occurred when using more than half of the device memory on the NI 5442 and NI 5450. |
133813 | Alignment of markers and other events to the analog output has been improved slightly within the existing specifications. The default unit for setting event delays on the NI 5450 is now samples, as it is on other signal generators. |
Bug ID | Fixed Issue |
104259 | Fixed an issue that incorrectly allowed users to write scripts while in the Generating state. |
103305 | Decreased minimum frequency step duration in Frequency List output mode for the NI 5402, NI 5406, NI 5441, and NI 5442 devices. The on-the-fly OSP carrier frequency change time for the NI 5441 and NI 5442 devices was also decreased. |
95208 | Fixed an issue that caused sine waves to have incorrect amplitudes when an offset was applied and flatness correction was enabled on the NI 5402, NI 5406, NI 5441, and NI 5442 devices. |
39673 | Improved streaming ease-of-use by automatically wrapping writes to streaming waveforms that cross the waveform boundary. |
Bug ID | Fixed Issue |
4E094973 | Fixed a streaming issue on the NI PXIe-5442. Streaming data to large waveforms that cross the midpoint of the device onboard memory may cause glitches to appear in the generated signal. |
4DQCUIFH | Improved internal clocking reliability for the NI PXIe-5442. |
4DJH2HJR, 4CQDTAAD | Fixed several issues with NI-FGEN for LabVIEW Real-Time systems. Upgrading from a previous version of NI-FGEN to NI-FGEN 2.5 could cause you to be unable to download the software to the target. Additionally, some devices may not have been usable with the LabVIEW Real-Time Module. |
API Changes by Release
VIs | niFgen Get Stream Endpoint Handle |
niFgen Manual Enable P2P Stream | |
niFgen Configure P2P Endpoint Fullness Start Trigger | |
niFgen Write P2P Endpoint I16 | |
Functions | ViStatus _VI_FUNC niFgen_GetStreamEndpointHandle (ViSession vi, ViConstString streamEndpoint, ViInt32* readerHandle); |
ViStatus _VI_FUNC niFgen_ManualEnableP2PStream (ViSession vi, ViConstString endpointName); | |
ViStatus _VI_FUNC niFgen_ConfigureP2PEndpointFullnessStartTrigger (ViSession vi, ViInt32 p2pEndpointFullnessLevel); | |
ViStatus _VI_FUNC niFgen_WriteP2PEndpointI16 (ViSession vi, ViConstString endpointName, ViInt32 numberOfSamples, ViInt16 endpointData[]); | |
ViStatus _VI_FUNC niFgen_ResetAttribute (ViSession vi, ViConstString channelName, ViAttr attributeId); | |
ViStatus _VI_FUNC niFgen_SetAttributeViInt64 (ViSession vi, ViConstString channelName, ViAttr attributeId, ViInt64 value); | |
ViStatus _VI_FUNC niFgen_CheckAttributeViInt64 (ViSession vi, ViConstString channelName, ViAttr attributeId, ViInt64 value); | |
ViStatus _VI_FUNC niFgen_GetAttributeViInt64 (ViSession vi, ViConstString channelName, ViAttr attributeId, ViInt64 *value); | |
Properties | P2P Enabled |
Destination Channels | |
Endpoint Size | |
Space Available in Endpoint | |
Most Space Available in Endpoint | |
Endpoint Count | |
Data Transfer Permission Interval | |
Data Transfer Permission Initial Credits | |
Manual Configuration Enabled | |
Data Transfer Permission Address | |
Data Transfer Permission Address Type | |
Endpoint Window Address | |
Endpoint Window Address Type | |
Endpoint Window Size | |
Done Notification Address | |
Done Notification Address Type | |
Done Notification Value | |
P2P Endpoint Fullness Start Trigger Level | |
Attributes | NIFGEN_ATTR_P2P_ENABLED |
NIFGEN_ATTR_P2P_DESTINATION_CHANNELS | |
NIFGEN_ATTR_P2P_ENDPOINT_SIZE | |
NIFGEN_ATTR_P2P_SPACE_AVAILABLE_IN_ENDPOINT | |
NIFGEN_ATTR_P2P_MOST_SPACE_AVAILABLE_IN_ENDPOINT | |
NIFGEN_ATTR_P2P_ENDPOINT_COUNT | |
NIFGEN_ATTR_P2P_DATA_TRANSFER_PERMISSION_INTERVAL | |
NIFGEN_ATTR_P2P_DATA_TRANSFER_PERMISSION_INITIAL_CREDITS | |
NIFGEN_ATTR_P2P_MANUAL_CONFIGURATION_ENABLED | |
NIFGEN_ATTR_P2P_DATA_TRANSFER_PERMISSION_ADDRESS | |
NIFGEN_ATTR_P2P_DATA_TRANSFER_PERMISSION_ADDRESS_TYPE | |
NIFGEN_ATTR_P2P_ENDPOINT_WINDOW_ADDRESS | |
NIFGEN_ATTR_P2P_ENDPOINT_WINDOW_ADDRESS_TYPE | |
NIFGEN_ATTR_P2P_ENDPOINT_WINDOW_SIZE | |
NIFGEN_ATTR_P2P_DONE_NOTIFICATION_ADDRESS | |
NIFGEN_ATTR_P2P_DONE_NOTIFICATION_ADDRESS_TYPE | |
NIFGEN_ATTR_P2P_DONE_NOTIFICATION_VALUE | |
NIFGEN_ATTR_P2P_ENDPOINT_FULLNESS_START_TRIGGER_LEVEL |
VI | niFgen Create Waveform (Complex WDT) |
Function | ViStatus _VI_FUNC niFgen_CalAdjustADC (ViSession vi, ViConstString Channel_Name, ViInt32 Configuration, ViReal64 Voltages_Measured_Externally[], ViReal64 Voltages_Measured_With_CalADC[]); |
Properties | Module Revision |
Compensate for Filter Group Delay | |
Attributes | NIFGEN_ATTR_MODULE_REVISION |
NIFGEN_ATTR_OSP_COMPENSATE_FOR_FILTER_GROUP_DELAY |
niFgen_CalAdjustCalADC
VI | niFgen Configure Channels |
Function | ViStatus _VI_FUNC niFgen_ConfigureChannels(ViSession vi, ViConstString channels); |
Properties | Channel Delay |
Common Mode Offset | |
Exported Sample Clock Timebase Output Terminal | |
External Sample Clock Multiplier | |
Frequency Shift | |
Idle Behavior | |
Idle Value | |
Maximum Bandwidth | |
Maximum In-Flight Read Requests | |
OSP Mode | |
PCI DMA Optimizations Enabled | |
Preferred Packet Size | |
Sample Clock Timebase Rate | |
Sample Clock Timebase Source | |
Terminal Configuration | |
Wait Behavior | |
Wait Value | |
Attributes | NIFGEN_ATTR_CHANNEL_DELAY |
NIFGEN_ATTR_COMMON_MODE_OFFSET | |
NIFGEN_ATTR_DATA_TRANSFER_MAXIMUM_BANDWIDTH | |
NIFGEN_ATTR_DATA_TRANSFER_MAXIMUM_IN_FLIGHT_READS | |
NIFGEN_ATTR_DATA_TRANSFER_PCI_DMA_OPTIMIZATIONS_ENABLED | |
NIFGEN_ATTR_DATA_TRANSFER_PREFERRED_PACKET_SIZE | |
NIFGEN_ATTR_EXPORTED_SAMPLE_CLOCK_TIMEBASE_OUTPUT_TERMINAL | |
NIFGEN_ATTR_EXTERNAL_SAMPLE_CLOCK_MULTIPLIER | |
NIFGEN_ATTR_IDLE_BEHAVIOR | |
NIFGEN_ATTR_IDLE_VALUE | |
NIFGEN_ATTR_OSP_FREQUENCY_SHIFT | |
NIFGEN_ATTR_OSP_MODE | |
NIFGEN_ATTR_SAMPLE_CLOCK_TIMEBASE_RATE | |
NIFGEN_ATTR_SAMPLE_CLOCK_TIMEBASE_SOURCE | |
NIFGEN_ATTR_TERMINAL_CONFIGURATION | |
NIFGEN_ATTR_WAIT_BEHAVIOR | |
NIFGEN_ATTR_WAIT_VALUE |
Properties | Done Event Delay |
Marker Event Delay | |
Started Event Delay | |
Done Event Delay Units | |
Marker Event Delay Units | |
Started Event Delay Units | |
Attributes | NIFGEN_ATTR_DONE_EVENT_DELAY |
NIFGEN_ATTR_MARKER_EVENT_DELAY | |
NIFGEN_ATTR_STARTED_EVENT_DELAY | |
NIFGEN_ATTR_DONE_EVENT_DELAY_UNITS | |
NIFGEN_ATTR_MARKER_EVENT_DELAY_UNITS | |
NIFGEN_ATTR_STARTED_EVENT_DELAY_UNITS |
Attributes | NIFGEN_ATTR_STREAMING_WAVEFORM_HANDLE |
NIFGEN_ATTR_ARB_MARKER_POSITION | |
NIFGEN_ATTR_ARB_REPEAT_COUNT | |
NIFGEN_ATTR_STREAMING_SPACE_AVAILABLE_IN_WAVEFORM | |
NIFGEN_ATTR_SAMPLE_CLOCK_SOURCE | |
NIFGEN_ATTR_REFERENCE_CLOCK_SOURCE | |
NIFGEN_ATTR_FLATNESS_CORRECTION_ENABLED | |
NIFGEN_ATTR_SCRIPT_TO_GENERATE | |
NIFGEN_ATTR_MARKER_EVENTS_COUNT | |
NIFGEN_ATTR_SCRIPT_TRIGGERS_COUNT | |
NIFGEN_ATTR_DATA_MARKER_EVENTS_COUNT | |
NIFGEN_ATTR_STREAMING_WAVEFORM_NAME | |
NIFGEN_ATTR_SCRIPT_TRIGGER_TYPE | |
NIFGEN_ATTR_DIGITAL_EDGE_SCRIPT_TRIGGER_SOURCE | |
NIFGEN_ATTR_DIGITAL_EDGE_SCRIPT_TRIGGER_EDGE | |
NIFGEN_ATTR_DIGITAL_LEVEL_SCRIPT_TRIGGER_SOURCE | |
NIFGEN_ATTR_DIGITAL_LEVEL_SCRIPT_TRIGGER_ACTIVE_LEVEL | |
NIFGEN_ATTR_EXPORTED_SCRIPT_TRIGGER_OUTPUT_TERMINAL | |
NIFGEN_ATTR_START_TRIGGER_TYPE | |
NIFGEN_ATTR_DIGITAL_EDGE_START_TRIGGER_SOURCE | |
NIFGEN_ATTR_DIGITAL_EDGE_TRIGGER_EDGE | |
NIFGEN_ATTR_EXPORTED_START_TRIGGER_OUTPUT_TERMINAL | |
NIFGEN_ATTR_READY_FOR_START_EVENT_OUTPUT_TERMINAL | |
NIFGEN_ATTR_READY_FOR_START_EVENT_LEVEL_ACTIVE_LEVEL | |
NIFGEN_ATTR_MARKER_EVENT_OUTPUT_TERMINAL | |
NIFGEN_ATTR_MARKER_EVENT_PULSE_POLARITY | |
NIFGEN_ATTR_MARKER_EVENT_PULSE_WIDTH | |
NIFGEN_ATTR_MARKER_EVENT_PULSE_WIDTH_UNITS | |
NIFGEN_ATTR_MARKER_EVENT_OUTPUT_BEHAVIOR | |
NIFGEN_ATTR_MARKER_EVENT_TOGGLE_INITIAL_STATE | |
NIFGEN_ATTR_STARTED_EVENT_OUTPUT_TERMINAL | |
NIFGEN_ATTR_STARTED_EVENT_LEVEL_ACTIVE_LEVEL | |
NIFGEN_ATTR_STARTED_EVENT_PULSE_POLARITY | |
NIFGEN_ATTR_STARTED_EVENT_OUTPUT_BEHAVIOR | |
NIFGEN_ATTR_STARTED_EVENT_PULSE_WIDTH_UNITS | |
NIFGEN_ATTR_STARTED_EVENT_PULSE_WIDTH | |
NIFGEN_ATTR_DONE_EVENT_OUTPUT_TERMINAL | |
NIFGEN_ATTR_DONE_EVENT_LEVEL_ACTIVE_LEVEL | |
NIFGEN_ATTR_DONE_EVENT_PULSE_POLARITY | |
NIFGEN_ATTR_DONE_EVENT_OUTPUT_BEHAVIOR | |
NIFGEN_ATTR_DONE_EVENT_PULSE_WIDTH_UNITS | |
NIFGEN_ATTR_DONE_EVENT_PULSE_WIDTH | |
NIFGEN_ATTR_DATA_MARKER_EVENT_DATA_BIT_NUMBER | |
NIFGEN_ATTR_DATA_MARKER_EVENT_LEVEL_POLARITY | |
NIFGEN_ATTR_DATA_MARKER_EVENT_OUTPUT_TERMINAL | |
NIFGEN_ATTR_ALL_MARKER_EVENTS_LIVE_STATUS | |
NIFGEN_ATTR_MARKER_EVENT_LIVE_STATUS | |
NIFGEN_ATTR_READY_FOR_START_EVENT_LIVE_STATUS | |
NIFGEN_ATTR_ALL_MARKER_EVENTS_LATCHED_STATUS | |
NIFGEN_ATTR_MARKER_EVENT_LATCHED_STATUS | |
NIFGEN_ATTR_DONE_EVENT_LATCHED_STATUS | |
NIFGEN_ATTR_STARTED_EVENT_LATCHED_STATUS | |
NIFGEN_ATTR_EXPORTED_SAMPLE_CLOCK_OUTPUT_TERMINAL | |
NIFGEN_ATTR_EXPORTED_REFERENCE_CLOCK_OUTPUT_TERMINAL | |
NIFGEN_ATTR_EXPORTED_ONBOARD_REFERENCE_CLOCK_OUTPUT_TERMINAL | |
NIFGEN_ATTR_EXPORTED_SAMPLE_CLOCK_TIMEBASE_OUTPUT_TERMINAL | |
NIFGEN_ATTR_SYNC_OUT_OUTPUT_TERMINAL | |
NIFGEN_ATTR_DIRECT_DMA_ENABLE | |
NIFGEN_ATTR_DIRECT_DMA_WINDOW_SIZE | |
NIFGEN_ATTR_DIRECT_DMA_WINDOW_ADDRESS | |
Functions | ViStatus _VI_FUNC niFgen_AllocateNamedWaveform(ViSession vi, ViConstString channelName, ViConstString wfmName, ViInt32 numberOfSamples); |
ViStatus _VI_FUNC niFgen_SetNamedWaveformNextWritePosition(ViSession vi, ViConstString channelName, ViConstString wfmName, ViInt32 relativeTo, ViInt32 offset); | |
ViStatus _VI_FUNC niFgen_WriteNamedWaveformF64(ViSession vi, ViConstString channelName, ViConstString wfmName, ViInt32 numberOfSamples, ViReal64 wfmData[]); | |
ViStatus _VI_FUNC niFgen_WriteNamedWaveformI16(ViSession vi, ViConstString channelName, ViConstString wfmName, ViInt32 numberOfSamples, ViInt16 wfmData[]); | |
ViStatus _VI_FUNC niFgen_WriteNamedWaveformComplexF64(ViSession vi, ViConstString channelName, ViConstString wfmName, ViInt32 numberOfSamples, NIComplexNumber wfmData[]); | |
ViStatus _VI_FUNC niFgen_WriteNamedWaveformComplexI16(ViSession vi, ViConstString channelName, ViConstString wfmName, ViInt32 numberOfSamples, NIComplexI16 wfmData[]); | |
ViStatus _VI_FUNC niFgen_DeleteNamedWaveform(ViSession vi, ViConstString channelName, ViConstString wfmName); | |
ViStatus _VI_FUNC niFgen_WriteScript(ViSession vi, ViConstString channelName, ViConstString script); | |
ViStatus _VI_FUNC niFgen_DeleteScript(ViSession vi, ViConstString channelName, ViConstString scriptName); | |
ViStatus _VI_FUNC niFgen_ExportSignal(ViSession vi, ViInt32 signal, ViConstString signalIdentifier, ViConstString outputTerminal); | |
ViStatus _VI_FUNC niFgen_SendSoftwareEdgeTrigger(ViSession vi, ViInt32 triggerName, ViConstString triggerIdentifier); | |
ViStatus _VI_FUNC niFgen_ConfigureDigitalEdgeStartTrigger(ViSession vi, ViConstString source, ViInt32 edge); | |
ViStatus _VI_FUNC niFgen_ConfigureSoftwareEdgeStartTrigger(ViSession vi); | |
ViStatus _VI_FUNC niFgen_DisableStartTrigger(ViSession vi); | |
ViStatus _VI_FUNC niFgen_ConfigureDigitalEdgeScriptTrigger(ViSession vi, ViConstString triggerID, ViConstString source, ViInt32 edge); | |
ViStatus _VI_FUNC niFgen_ConfigureDigitalLevelScriptTrigger(ViSession vi, ViConstString triggerID, ViConstString source, ViInt32 level); | |
ViStatus _VI_FUNC niFgen_ConfigureSoftwareEdgeScriptTrigger(ViSession vi, ViConstString triggerID); | |
ViStatus _VI_FUNC niFgen_DisableScriptTrigger(ViSession vi, ViConstString triggerID); | |
ViStatus _VI_FUNC niFgen_WriteComplexBinary16Waveform(ViSession vi, ViConstString channelName, ViInt32 waveformHandle, ViInt32 numberOfSamples, NIComplexI16 wfmData[]); | |
ViStatus _VI_FUNC niFgen_InitializeFlatnessCalibration(ViSession vi); | |
ViStatus _VI_FUNC niFgen_CalAdjustFlatness(ViSession vi, ViConstString channelName, ViInt32 configuration, ViReal64 requestedAmplitude, ViReal64* frequencies, ViReal64* measuredAmplitudes, ViInt32 numberOfMeasurements); | |
ViStatus _VI_FUNC niFgen_ConfigureSampleClockSource(ViSession vi, ViConstString sampleClockSource); | |
Values | Output Mode: NIFGEN_VAL_OUTPUT_SCRIPT |
New attributes and functions: See niFgen.h file for values supported by new attributes and functions |
niFgen Configure Ref Clock Frequency VI
niFgen Configure Ref Clock Source VI
niFgen Configure Trigger VI
niFgen Configure Update Clock Source VI
niFgen Send Software Trigger VI
niFgen_ConfigureReferenceClockFrequency
niFgen_ConfigureReferenceClockSource
niFgen_ConfigureTriggerSource
niFgen_ConfigureUpdateClockSource
niFgen_SendSoftwareTrigger
Attributes | NIFGEN_ATTR_DIGITAL_GAIN |
NIFGEN_ATTR_OSP_ENABLED | |
NIFGEN_ATTR_OSP_DATA_PROCESSING_MODE | |
NIFGEN_ATTR_OSP_IQ_RATE | |
NIFGEN_ATTR_OSP_CARRIER_ENABLED | |
NIFGEN_ATTR_OSP_CARRIER_FREQUENCY | |
NIFGEN_ATTR_OSP_CARRIER_PHASE_I | |
NIFGEN_ATTR_OSP_CARRIER_PHASE_Q | |
NIFGEN_ATTR_OSP_FIR_FILTER_TYPE | |
NIFGEN_ATTR_OSP_FIR_FILTER_ENABLED | |
NIFGEN_ATTR_OSP_FIR_FILTER_INTERPOLATION | |
NIFGEN_ATTR_OSP_CIC_FILTER_ENABLED | |
NIFGEN_ATTR_OSP_CIC_FILTER_INTERPOLATION | |
NIFGEN_ATTR_OSP_FIR_FILTER_ROOT_RAISED_COSINE_ALPHA | |
NIFGEN_ATTR_OSP_FIR_FILTER_RAISED_COSINE_ALPHA | |
NIFGEN_ATTR_OSP_FIR_FILTER_FLAT_PASSBAND | |
NIFGEN_ATTR_OSP_FIR_FILTER_GAUSSIAN_BT | |
NIFGEN_ATTR_OSP_CIC_FILTER_GAIN | |
NIFGEN_ATTR_OSP_PRE_FILTER_GAIN_I | |
NIFGEN_ATTR_OSP_PRE_FILTER_GAIN_Q | |
NIFGEN_ATTR_OSP_PRE_FILTER_OFFSET_I | |
NIFGEN_ATTR_OSP_PRE_FILTER_OFFSET_Q | |
NIFGEN_ATTR_OSP_OVERFLOW_ERROR_REPORTING | |
NIFGEN_ATTR_OSP_OVERFLOW_STATUS | |
Functions | ViStatus niFgen_ConfigureCustomFIRFilterCoefficients (ViSession vi, ViConstString channelName, ViInt32 numberOfCoefficients, ViReal64* coefficients) |
ViStatus niFgen_GetFIRFilterCoefficients (ViSession vi, ViConstString channelName, ViInt32 arraySize, ViReal64* coefficients, ViInt32* numberOfCoefficientsRead) | |
ViStatus niFgen_CreateWaveformComplexF64 (ViSession vi, ViConstString channelName, ViInt32 numberOfSamples, niFgen_ComplexF64 wfmData[], ViInt32 *wfmHandle) | |
ViStatus niFgen_WriteWaveformComplexF6 (ViSession vi, ViConstString channelName, ViInt32 numberOfSamples, niFgen_ComplexF64 data[], ViInt32 wfmHandle) | |
Values | OSP Data Processing Mode: NIFGEN_VAL_OSP_REAL NIFGEN_VAL_OSP_COMPLEX |
OSP FIR Filter Type: NIFGEN_VAL_OSP_FLAT NIFGEN_VAL_OSP_RAISED_COSINE NIFGEN_VAL_OSP_ROOT_RAISED_COSINE NIFGEN_VAL_OSP_GAUSSIAN NIFGEN_VAL_OSP_CUSTOM | |
OSP Overflow Error Reporting: NIFGEN_VAL_ERROR_REPORTING_ERROR NIFGEN_VAL_ERROR_REPORTING_DISABLED | |
OSP Overflow Status: NIFGEN_VAL_OSP_OVERFLOW_NONE NIFGEN_VAL_OSP_OVERFLOW_PRE_FILTER_GAIN_I NIFGEN_VAL_OSP_OVERFLOW_PRE_FILTER_GAIN_Q NIFGEN_VAL_OSP_OVERFLOW_PRE_FILTER_OFFSET_I NIFGEN_VAL_OSP_OVERFLOW_PRE_FILTER_OFFSET_Q NIFGEN_VAL_OSP_OVERFLOW_FIR_FILTER_I NIFGEN_VAL_OSP_OVERFLOW_FIR_FILTER_Q NIFGEN_VAL_OSP_OVERFLOW_CIC_FILTER_I NIFGEN_VAL_OSP_OVERFLOW_CIC_FILTER_Q NIFGEN_VAL_OSP_OVERFLOW_COMPLEX_DATA |
Notice Regarding Microsoft Silverlight Installation and RedistributionInstalling Microsoft Silverlight
Using Microsoft Silverlight
Redistribution of Microsoft Silverlight