Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://pcmv.cn/thread-490-1-1.html
视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://pcmv.cn/thread-26524-1-1.html
NI-DMM 2.8 Driver Win32/64Eng NI数字万用表驱动程序2.8下载
NI-DMM
NI-DMM支持使用NI数字万用表的客户。
NI-DMM是与所有NI可编程数字万用表(DMM)进行通信必需的NI仪器驱动程序。NI-DMM是一种兼容可互换虚拟仪器(IVI)的仪器驱动程序,提供了一系列操作和属性,可以执行波形或信号发生器的功能,而且包含了交互式软件前面板和示例。
Win32/64Eng
2.8
文件大小: 987717127 字节 (941.96 MB)
修改日期: 2009-09-05 04:46
MD5: 017ae3eab91a8ff38fb7038a6f7e5f89(官方正确)
SHA1: 826a75b2be724a119528903e62ef3fd58d1e336d
SHA256: ff9458c5ebe41ca14579cb07a219aad19c5c0ac97dd924eec9f8a4a8e31f0aeb
CRC32: 00f24279
百度网盘与NI官方下载地址:
NI-DMM 2.8 Driver Win32/64Eng NI数字万用表驱动程序2.8下载
http://pcmv.cn/thread-26266-1-1.html?fromuid=9
(出处: 视觉论坛VISIONBBS|视觉之家VISIONHOME)
NI-DMM 2.8 Readme
New Features in NI-DMM 2.8
Supported Hardware
System Requirements
Installed File Names and Locations
Software
Documentation
Uninstalling/Modifying NI-DMM 2.8
Examples
Obsolete VIs/Functions
Known Issues
Changes by Release
New Features in NI-DMM 2.8
Support for the NI USB-4065.
Supported Hardware
Hardware Product | Windows XP/2000 | Windows Vista |
NI PXI-4072 | √ | √1 |
NI PXI-4071 | √ | √1 |
NI PXI-4070 | √ | √1 |
NI PCI-4070 | √ | √ |
NI PXI-4065 | √ | √1 |
NI PCIe-4065 | √ | √ |
NI PCI-4065 | √ | √ |
NI USB-4065 | √ | √ |
NI PXI-4060 | √ | X |
NI PCI-4060 | √ | X |
NI PCMCIA-4050 | √ | X |
NI PXI-4022 | √ | √1 |
1 Notice that MXI-4 is supported on Windows Vista/XP/2000, but MXI-3 is supported on only Windows XP/2000. |
System RequirementsMinimum System Requirements
Recommended System
Application Development Environments
LabVIEW 7.1, 8.0, 8.2, and 8.5
LabVIEW Real-Time Module 7.1.1, 8.0, 8.2, and 8.5 (NI PXI-4065, NI PXI-4070, NI PXI-4071, and NI PXI-4072 devices only)
LabWindows™/CVI™ 7.1, 8.0, and 8.1.
LabWindows™/CVI™ Real-Time Module (NI PXI-4065, NI PXI-4070, NI PXI-4071, and NI PXI-4072 devices only)
Microsoft Visual C++ (MSVC) 6.0 or later
Microsoft Visual Basic 6.0
Processor—Pentium III/Celeron 600 MHz or equivalent
RAM—256 MB
A screen resolution of 1024 x 768
Processor—Pentium 200 MHz or equivalent
RAM—64 MB
Microsoft Internet Explorer 5.5 or later
A screen resolution of 800 x 600 with 256 colors
Windows Vista/XP/2000, with all available critical updates and service packs
Installed File Names and LocationsSoftware
Item | Installed Location on Windows XP/2000 and Windows Vista (32-bit version) | Installed Location on Windows Vista x64 Edition |
NI-DMM | Program FilesIVIDrivers iDMM | Program Files (x86)IVIDrivers iDMM |
Documentation | Program FilesIVIDrivers iDMMDocumentation | Program Files (x86)IVIDrivers iDMMDocumentation |
NI-DMM LabVIEW support | <LabVIEW>instr.lib iDMM | <LabVIEW>instr.lib iDMM |
NI-DMM LabVIEW Examples | <LabVIEW>examplesinstr iDMM | <LabVIEW>examplesinstr iDMM |
NI-DMM CVI support | Program FilesIVIDrivers iDMM | Program Files (x86)IVIDrivers iDMM |
NI-DMM CVI Examples | <CVI>samples iDMM | <CVI>samples iDMM |
NI-DMM Function Panel | Program FilesIVIDrivers iDMM idmm.fp | Program Files (x86)IVIDrivers iDMM idmm.fp |
NI-DMM C/C++ Examples | <Measurement Studio>VCExamples iDMM | <Measurement Studio>VCExamples iDMM |
NI-DMM Header files | Program FilesIVIinclude | Program Files (x86)IVIinclude |
NI-DMM Import Library files | Program FilesIVILib | Program Files (x86)IVILib |
NI-DMM VB Examples | <Measurement Studio>VBSamples iDMM | <Measurement Studio>VBSamples iDMM |
NI-DMM DLL | Program FilesIVIBin | Program Files (x86)IVIBin |
DMM SFP (Soft Front Panel) | Program FilesIVIDrivers iDMM | Program Files (x86)IVIDrivers iDMM |
LabVIEW Run-Time Engine 8.2.1 | Program FilesNational InstrumentsShared LabVIEW Run-Time8.2.1 | Program Files (x86)National InstrumentsShared LabVIEW Run-Time8.2.1 |
NI SignalExpress 2.5 | Program FilesIVIDrivers iDMMSignalExpress | Program Files (x86)IVIDrivers iDMMSignalExpress |
NI-DAQ 8.6 | Program FilesNational InstrumentsNI-DAQ | Program Files (x86)National InstrumentsNI-DAQ |
IVI Compliance Package 3.1 | Program FilesNational InstrumentsIVI | Program Files (x86)National InstrumentsIVI |
NI-VISA 4.1 | WINDOWSsystem32 | WINDOWSsystem32 |
Documentation
NI-DMM 2.8 ReadmeNI Digital Multimeters Getting Started Guide
NI Digital Multimeters Help
NI PCMCIA-4050 SpecificationsNI PXI/PCI-4060 SpecificationsNI 4065 SpecificationsNI 4070/4072 SpecificationsNI 4071 SpecificationsNI 4065 6½—Digit Calibration ProcedureNI 4070/4072 6½—Digit FlexDMM Calibration Procedure
NI 4071 7½—Digit FlexDMM Calibration ProcedureUninstalling/Modifying NI-DMM 2.8
Launch the Control Panel by selecting Start»Control Panel.
Double-click Add or Remove Programs.
Select National Instruments Software.
Click Change/Remove.
Select NI-DMM 2.8 from the dialog box that appears.
Click Remove to uninstall the product; click Modify to change the components that are installed.
Launch the Control Panel by selecting Start»Control Panel.
Double-click Programs and Features.
Select National Instruments Software.
Click the Uninstall/Change button.
Select NI-DMM 2.8 from the dialog box that appears.
Click Remove to uninstall the product; click Modify to change the components that are installed.
Examples
Obsolete VIs/Functions
Obsolete |
niDMM Calculate Accuracy |
niDMM Clear Error Info |
niDMM Get Error Info |
niDMM Configure Auto Zero Mode (LabVIEW only) |
Known Issues
The links in the function panel help in LabWindows/CVI versions 7.1 and 7.1.1 will not work unless you have downloaded the most recent version of the launchhelp.js file. Instructions for downloading and installing the file can be found in the KnowledgeBase entry Why Do I Get "Object Expected" Error When Opening Links in Function Panel Help? You can locate this KB by going to ni.com/info and entering rdnkbe in the Info Code field.
If you click a topic link in the NI-DMM C Reference Help section of the NI Digital Multimeters Help, you cannot use the Back button in the HTML Help window toolbar to return to the original topic.
The NI PCI/PCIe-4065 may produce undesired triggers on the Voltmeter Complete signal when configured for Auto Range measurements. To avoid undesired performance, do not trigger while configured for an Auto Range acquisition.
NI recommends that you disable Windows power management modes, such as sleep, standby, and hibernate, when using this product. These modes terminate any NI-DMM operation in progress. Notice that in Windows Vista or on a laptop computer, the default power management settings are likely to enable sleep mode.
When you run setup.exe to install the software from the CD, you are prompted to choose whether you want to always trust software from National Instruments. If you do not select this option, your installation may be interrupted by one or more Microsoft Windows security dialog boxes. However, if you run setup from the command line, you will not receive this prompt, and the installer will automatically install NI's Software Publisher Certificate to the your Windows Trusted Publisher Store. If you do not want to make this change to your Windows Trusted Publisher Store, do not choose this installation method.
The NI PXI-4070 can not operate as a Traditional DAQ (Legacy) SCXI controller in Windows Vista.
The NI PXI-4070 was upgraded and new revisions of the device beginning with 191485A-01 are incompatible with versions of NI-DMM prior to 2.3. NI-DMM 2.3 and later provides support for all revisions of the NI PXI-4070.
The NI 4065/4070/4071/4072 can be programmed only with NI-DMM. NI-DAQ function calls and DAQ virtual channels are not supported by the NI 4065/4070/4071/4072. Using NI-DAQ with the NI 4065/4070/4071/4072 can cause an error that requires a system reboot.
In MAX under the Configuring Device window for the NI 4070 in Traditional DAQ (Legacy), Run Test Panels is grayed out.
In MAX under the Configuring Device window for the NI 4070 in Traditional DAQ (Legacy), Test Resources always indicates the device has passed the test regardless of the device's condition.
If you are replacing the NI 4060 with the NI 4065 or NI 4070/4071/4072 in an application that uses triggering, consider the following differences in behavior:
If your application relies on the routing behavior of the NI 4060 by not explicitly calling niDMM Configure Measurement Complete Destination, you must modify your application by calling the VI/function. Alternately, the NI 4065 and NI 4070/4071/4072 can emulate NI 4060 routing behavior by specifying the following registry key:
HKEY_LOCAL_MACHINESoftwareNational InstrumentsNI-DMMCurrentVersionlegacyMCRoute
where the value is a DWORD set to 1.
Without this registry key, NI-DMM sets NIDMM_ATTR_MEAS_COMPLETE_DEST to NONE for the NI 4065 and NI 4070/4071/4072. With this registry key, NI-DMM sets NIDMM_ATTR_MEAS_COMPLETE_DEST to the location where SCXI communication is configured in the application.
The NI 4060 configured as an SCXI controller automatically sets the Measurement Complete (MC) destination to the location where SCXI is configured (external or internal PXI/SCXI trigger lines).
The NI 4065 and NI 4070/4071/4072 configured as an SCXI controller automatically sets the MC destination to NONE.
There are known DLL collision issues with the Visual Basic debugger and National Instruments device drivers. A support DLL used by NI-DMM fails to load if Visual Basic has already loaded another DLL into the same address space. More information on this issue and solution are documented in KnowledgeBase entry 2Q1HG8A6. Refer to ni.com/support to access the KnowledgeBase.
Changes by ReleaseChanges in NI-DMM 2.8 from NI-DMM 2.7.2
Support for the NI USB-4065.
New behavior: LC Compensation no longer returns an error when used with a PXI-4072. This issue was introduced in NI-DMM 2.7.1.
Changes in NI-DMM 2.7.2 from NI-DMM 2.7.1
Support for LabVIEW 8.5.
Changes in NI-DMM 2.7.1 from NI-DMM 2.7
Support for the NI PXI-4065.
New behavior: For NI 4065 and NI 407x devices, NI-DMM 2.7 incorrectly swapped the Settling Time behavior of triggered and non-triggered multipoint measurements. This behavior resulted in overly-short Settling Times in triggering/switching applications, which could affect measurement quality, and overly-long Settling Times in non-triggered applications. This behavior has been corrected in NI-DMM 2.7.1.
Changes in NI-DMM 2.7 from NI-DMM 2.6
Support for Windows Vista.
Datalogger support in NI LabVIEW SignalExpress 2.0 and later.
Changes in NI-DMM 2.6 from NI-DMM 2.5
Support for the NI PCI/PCIe-4065.
Introduction of the niDMM Cal Adjust Linearization VI and the niDMM_CalAdjustLinearization function.
A change was made in NI-DMM 2.6 to ensure that NI 407x devices operate as expected in industrial PC chassis and across MXI configurations (including MXI Express).
A change was made in NI-DMM 2.6 to ensure that the NI 407x front-end is fully configured before returning from niDMM Initiate or niDMM Control (when the Control Action parameter is set to "Commit").
On versions of NI-DMM prior to 2.6, NI 4060 users may encounter a rare intermittent behavior that results in a hang or crash. This behavior is typically encountered upon initializing the device a second time within the same instance of an application environment such as LabVIEW. This behavior may also be seen during a calibration routine within Calibration Executive and has been corrected as of NI-DMM version 2.6.
Changes in NI-DMM 2.5 from NI-DMM 2.4
Introduction of the DMM/Switch Express VI.
Introduction of the niDMM Control VI and the niDMM_Control function.
Support for LabVIEW 8.0.
Support for LabVIEW Real-Time Module 8.0 (NI PXI/PCI-4070, NI PXI-4071, and NI PXI-4072 only)
New behavior: Initializing a session with the niDMM Initialize VI or the niDMM_init function now closes any other existing sessions open to the same device in the same process. Calling the niDMM Initialize VI or the niDMM_init function therefore always results in the creation of a new session rather than returning an existing session.
Changes in NI-DMM 2.4 from NI-DMM 2.3
Support for the NI PXI-4071.
Introduction of the NI-DMM Express VI.
Support for NI SignalExpress 1.1.
Introduction of the niDMM Config Measurement VI and the niDMM_ConfigureMeasurementDigits and niDMM_ConfigureMeasurementAbsolute functions.
Changes in NI-DMM 2.3 from NI-DMM 2.2
Support for the NI PXI-4072.
Support for the LabVIEW Real-Time Module has been added. For more information about using NI-DMM with the LabVIEW Real-Time Module, launch the NI Digital Multimeters Help and select Programming with NI-DMM»Getting Started»Using NI-DMM in LabVIEW»Considerations for Using the LabVIEW Real-Time Module.
Inclusion of Measurement Studio C++ interface to NI-DMM.
Changes in NI-DMM 2.2 from NI-DMM 2.1
Support for the NI PCI-4070.
Support for the NI PXI/PCI-4070 devices to control an SCXI chassis that contains NI-DAQmx SCXI modules has been added (NI PXI/PCI-4070 only).
Support in MAX for the Self-Test and Self-Calibrate buttons for NI-DAQmx devices has been added (NI PXI/PCI-4070 only).
Support for the "break-on-library-error" feature in LabWindows/CVI (CVI user protection).
NI-DMM removes Offset Compensation Ohms capability for ranges 100 kΩ and greater.
NI-DMM corrects the resistance reference adjustment function of the external calibration procedure.
The IVI Configuration Store file format now requires that all names be case-sensitive. If you use logical names, driver session names, or virtual names in your program, make sure that the name you use matches the name defined in the IVI Configuration Store file exactly, without any variations in the case of the characters in the name.
Changes in NI-DMM 2.1 from NI-DMM 2.0
Self-test and simulation have been added for the NI PXI-4070.
The 1 MΩ input resistance value is no longer valid for DC voltage measurements on the NI PXI-4070.
AC voltage measurements using the DC coupling on the NI PXI-4070 have been improved to account for a computational error.
A new error code, NIDMM_ERROR_INVALID_MEAS_COMP_DEST has been created. This error is returned if an Input Trigger or Sample Trigger source is set to the same value as the Measurement Complete (MC) destination.
The self-calibration algorithm for the NI PXI-4070 has been updated to improve the gain correction.
Resistance measurements have been improved for low resolutions that enable both ADC calibration and offset compensated ohms.