石鑫华视觉网| 东莞华视自动化科技有限公司|机器视觉商城|机器视觉论坛|淘宝店铺

机器视觉_石鑫华视觉网_光源_控制器_工业相机_镜头_视觉方案_NI_LabVIEW_Vision_VBAI_图像处理教程_论坛_商城_东莞华视自动化科技有限公司,机器视觉,工业相机,工业镜头,LED光源,图像处理,视觉方案,VBAI,LabVIEW

石鑫华视觉网,东莞华视自动化科技有限公司,机器视觉商城淘宝店,机器视觉网,机器视觉论坛,机器视觉光源,光源控制器,工业相机,工业镜头,视觉方案,机器视觉系统,图像处理教程,LabVIEW

当前位置: 首页 > 下载 >

NI Vision Acquisition Software 18.0视觉采集软件VAS1800版 兼

时间:2018-05-21来源:石鑫华视觉网shixinhua.com 作者:石鑫华 点击:
NI Vision Acquisition Software 18.0视觉采集软件VAS18.0版 兼容LabVIEW VISION 2018
VAS18.0版(VAS1800)为2018年5月17日发布,支持最新的LabVIEW2018及NI VISION 2018,以及LabVIEW NXG2.1版本。


NI Vision Acquisition Software includes the following drivers:
  • NI-IMAQ is driver software for the following device types:
    • NI 17xx smart cameras
    • analog cameras
    • parallel digital cameras
    • Camera Link cameras
  • NI-IMAQdx is driver software for the following device types:
    • Camera Link cameras used with supported frame grabbers
    • NI 177x smart cameras
    • ISC-178x smart cameras
    • GigE Vision-compliant cameras
    • USB3 Vision-compliant cameras
    • IIDC/DCAM-compliant IEEE 1394 cameras
    • DirectShow-compatible cameras
    • Basler and Axis IP cameras
  • NI-IMAQ I/O is driver software for controlling reconfigurable input/output (RIO) on image acquisition devices and real-time targets. The following hardware is supported by NI-IMAQ I/O:
    • NI CVS-1457RT
    • NI CVS-1458
    • NI CVS-1458RT
    • NI CVS-1459
    • NI CVS-1459RT
    • NI EVS-1463
    • NI EVS-1463RT
    • NI EVS-1464
    • NI EVS-1464RT
    • NI PCI-8254R
    • NI PCIe-8255R
    • NI PCIe-8237R
    • NI PCIe-1473R
    • NI PCIe-1473R-LX110
    • NI 1483 FlexRIO Adapter Module
  • Note: New versions of Vision Acquisition Software no longer support the following hardware:
    • NI 1762 and 1764 Smart Cameras
    • NI CVS-1454, 1455, and 1456 Compact Vision Systems
  • Note: The EVS-146x series of controllers are not supported in LabVIEW 2016 or later.




System Requirements
The development computer must meet the following requirements to run NI Vision Acquisition Software:
Processor
Pentium 4 1 GHz or equivalent
Memory
512 MB RAM
Display
1,024 × 768 resolution video adapter with a 16-bit display
Minimum Recommended
Free Hard Disk Space
NI Vision Acquisition Software
3.5 GB
NI-IMAQ
1.5 GB
NI-IMAQdx
1.5 GB
NI-IMAQ I/O
2.5 GB
Operating System
  • Windows 10 (32- and 64-bit)
  • Windows 10 IoT Enterprise (64-bit)3
  • Windows 8.1 (32- and 64-bit)1
  • Windows 7 SP1 (32- and 64-bit)2
  • Windows Embedded Standard 7 SP1 (32- and 64-bit)2,3
  • Windows Server 2012 R2 (64-bit)1
  • Windows Server 2008 R2 SP1 (64-bit)2
Note  NI Vision Acquisition Software August 2016 dropped support for Windows Vista, Windows XP, Windows Server 2003, and installations of Windows 7 without any service packs. NI Vision Acquisition Software August 2016 and later will not install or run on an unsupported OS. You cannot deploy or distribute applications that use NI Vision Acquisition Software August 2016 or later to an unsupported OS. Additionally, after installing NI Vision Acquisition Software August 2016 or later, you cannot use any installers built on this computer with any version of LabVIEW, LabWindows™/CVI™, NI TestStand™, or Measurement Studio on an unsupported OS.

[url=]NI Application Software Support
The following table lists the NI application software versions, including service packs, supported by NI Vision Acquisition Software. The installer specifically allows side-by-side installations of NI Vision Acquisition Software for each of the supported versions of LabVIEW, enabling you to use NI Vision Acquisition Software with multiple versions of LabVIEW. National Instruments recommends that you install LabVIEW, LabVIEW Real-Time, and any other supported development environment before installing NI Vision Acquisition Software.
NI Application Software Versions Supported by NI Vision Acquisition Software
NI LabVIEW
2015, 2016, 2017, 2018
NI LabVIEW Real-Time Module
2015, 2016, 2017, 2018
NI LabVIEW FPGA Module
2015, 2016, 2017, 2018
NI LabVIEW NXG
2.1
NI LabWindows™/CVI™
2012, 2013, 2015, 2017
NI Vision Development Module
7.1 or later
NI Vision Builder for Automated Inspection
2.5 or later
NI Vision Acquisition Software .NET Support
NI Vision Acquisition Software February 2014 was the last version to release updated support for the .NET Framework 2.0, .NET Framework 3.5, and .NET language integration into Visual Studio 2005 and Visual Studio 2008. Visual Studio 2010 and later are not supported.
New versions of NI Vision Acquisition Software will not provide new .NET feature support or development. It is recommended that you begin new development in other supported development environments.
Vision Standards Support
The following table lists the machine vision and imaging standards supported by NI Vision Acquisition Software.
Machine Vision or Imaging Standard Version Supported by NI Vision Acquisition Software
Camera Link®
2.0
GenICam™
3.0.1
GigE Vision®
2.0 (select features)
IIDC
1.32
USB3 Vision®
1.0.1
New Features
This release of NI Vision Acquisition Software includes the following new features.
NI-IMAQ 18.0
  • Added support for PCIe-1437 frame grabbers
  • Addded support for LabVIEW 2018
NI-IMAQdx 18.0
  • Added support for LabVIEW 2018
  • Added support for LabVIEW NXG 2.1
    • For information about VAS support in LabVIEW NXG, visit ni.com/info and enter the Info Code VisionNXGGuide.
  • Added support for configuring Camera Link cameras in Windows using the following frame grabbers:
    • PCIe-1427
    • PCIe-1433
    • PCIe-1437
    • PXIe-1435
  • Added LabVIEW NXG support for Camera Link frame grabbers in System Designer
NI-IMAQ I/O 18.0
  • Added support for LabVIEW 2018

NI官方下载地址:
http://download.ni.com/support/softlib/vision/Vision%20Acquisition%20Software/18.0/VAS1800.zip
百度云盘下载:
链接: https://pan.baidu.com/s/1WeanjW2WEP5mRobXtTGxsw 
密码: 39gu
------分隔线----------------------------
石鑫华推荐